Thermoresistance with connecting head
IWT 340 - Resistance thermometers with connection head
- Application temperature:
- up to +380°C for GL-Design
- -200 to +600°C
- -50 to +400°C
- on inquiry
- Temperature sensor
- 1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
IWT 361 - Resistance thermometers with connection head
- Connection head:
- Form B according DIN 43 729
- Form BUZ for explosion-proof design according DIN 43 729
- on inquiry
- Protection classification
- IP 54 according DIN 60529
- on inquiry
- Application temperature
- -200 to +600°C
- -50 to +400°C
- on inquiry
- Temperature sensor
- 1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- on inquiry
IWT 348 - Resistance thermometers with connection head
- Connection head
- Form B according DIN 43 729
- Form BUZ for explosion-proof design according DIN 43 729
- on inquiry
- Protection classification
- IP 54 according DIN 60529
- on inquiry
- Application temperature
- -200 to +600°C
- -50 to +400°C
- on inquiry
- Temperature sensor
- 1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- on inquiry
IWT 354 - Resistance thermometers with connection head
- Connection head
- Form B according DIN 43 729
- Form BUZ for explosion-proof design according DIN 43 729
- on inquiry
- Protection classification
- IP 54 according DIN 60529
- on inquiry
- Application temperature
- up to +380°C for GL-Design
- -200 to +600°C
- -50 to +400°C
- on inquiry
- Temperature sensor
- 1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- on inquiry
IWT 357 - Resistance thermometer with exchangeable measuring insert, for welding in, for high working pressure.
- Connection head
- Form B according DIN 43 729
- Form BUZ for explosion-proof design according DIN 43 729
- on inquiry
- Protection classification
- IP 54 according DIN 60529<
- on inquiry
- Application temperature
- up to +380°C for GL-Design
- -200 to +600°C
- -50 to +400°C
- on inquiry
- Temperature sensor
- 1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- on inquiry
IWT 372 - Resistance thermometer for srewing in
- Connection head
- Form B according DIN 43 729
- Form BUZ for explosion-proof design according DIN 43 729
- on inquiry
- Protection classification
- IP 54 according DIN 60529
- on inquiry
- Application temperature
- up to +380°C for GL-Design
- -200 to +600°C
- -50 to +400°C
- on inquiry
- Temperature sensor
- 1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- on inquiry
IWT 373 - Resistance thermometer for srewing in
- Protection classification
- IP 54 according DIN 60529
- on inquiry
- Application temperature
- -200 to +600°C
- -50 to +400°C
- on inquiry
- Temperature sensor
- 1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- on inquiry
IWT 374 - Resistance thermometer with flange
- Connection head
- Form B according DIN 43 729
- Form BUZ for explosion-proof design according DIN 43 729
- on inquiry
- Protection classification
- IP 54 according DIN 60529
- on inquiry
- Application temperature
- -200 to +600°C
- -50 to +400°C
- on inquiry
- Temperature sensor
- 1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- 2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751
- 2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751
- on inquiry
IWT 352 WZ - Heatmeter resistance thermometer
- Connection head
- Form B according DIN 43 729
- Protection classification
- IP 54 according DIN 60529
- Application temperature
- 0 °C to 140 °C
- 0 °C to 200 °C
- Temperature sensor
- 1xPt 100 selected
IWT 361 WZ - Heatmeter resistance thermometer
- Connection head
- Form B according DIN 43 729
- Protection classification
- IP 54 according DIN 60529
- Application temperature
- 0 °C to 140 °C
- 0 °C to 200 °C
- Temperature sensor
- 1xPt 100 selected