ISA Instrument transformer testing
STS 5000 - Multifunction substation maintenance & commissioning test systems for current, voltage and power transformers
- Fully automatic
- Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000
- Variable output frequency: 15 - 500 Hz
- Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV)
- 2000 v AC high-pot test
- Local control by large color display
- PADS - Power Apparatus Diagnostic Software for automatic testing, assessment and report
- IEC 61850-9-2 communication protocol
- Patented technology for Capacitance and Tan Delta measurement
- USB interface and Ethernet interface for PC connection.
- Compact and lightweight.
STCS PLUS switch module
- Fast measurement and single set-up for all the tests
- Lower probability of connection errors
- Different cable is provided according to the dimensions of the transformer
- Removable lid for a more confortable use
- Ratio per tap
- No load current
- Vector group
- Short-circuit impedance
- Leakage reactance
- Winding resistance
- OLTC dynamic test
- Demagnetization
STS 4000 - Multifunction substation maintenance & commissioning test systems for current, voltage and power transformers
- Fully automatic
- Primary injection testing capabilities: up to 5000 A / 7000 A, with the optional module BUX 5000
- Variable output frequency: 15 - 500 Hz
- Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV)
- 2000 v AC high-pot test
- Local control by large color display
- PADS - Power Apparatus Diagnostic Software for automatic testing, assessment and report
- IEC 61850-9-2 communication protocol
- Patented technology for Capacitance and Tan Delta measurement
- USB interface and Ethernet interface for PC connection.
- Compact and lightweight.
eKAM - Electronic and automatic primary injection test system up to 2000 A, 3000 A and 5000 A
- Fully automatic
- Two portable units: control and current units
- High current output: up to 2000 A, 3000 A and 5000 A
- Variable output frequency: 15 - 500 Hz
- CT ratio, burden and polarity test
- Large graphic display
- Advanced Test & Data Management Software for test set control, results storage and analysis
- Step & touch plus ground resistance tests with STLG option
- Reduced timing test
- USB interface and Ethernet interface for PC connection
- IEC 61850-9-2 sample values protocol interface
- Compact and lightweight
T 3000 - Substation Maintenance and Commissioning Test Equipment
- Multi function primary test system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers
- Primary injection testing capabilities
- 3000 V AC high-pot test
- Generates up to 800 A (option up to 4000A with high current booster)
- Microhmmeter function (option): up to 400A DC
- RS232 interface for pc connection
- Possibility to store test results in T3000 local memory (up to 500 results)
- Compact and lightweight: 29 kg
T 2000 - Transformer Test Set
- Multi function system for testing: current, voltage and power transformers
- Current transformer excitation, ratio and polarity test set
- Primary injection testing capabilities
- 3000 V AC high-pot test
- Generates up to 800 A (option up to 4000A with high current booster)
- Microhmmeter function (option): up to 400A DC
- RS232 interface for pc connection
- Test results and settings are saved into local memory
- Compact and lightweight: 26 kg
BU 2000 - High Current Booster
- Option for T 2000 and T 3000 test equipment
- Option for primary current injection and transformer test equipment T 3000 and T 2000.
- Maximum current up to 4000 A
- Designed to avoid the power losses due to long cables connections
- Connected to T 2000 or T 3000 unit with long (up to 20 m) low power control cable
- Supplied with high current clamps and high current cables
KAM - Prüfsystem für Primärstromprüfungen
- Starkstromausgang bis zu 7000 A
- Leistungsstarker Ausgang bis zu 35 kVA
- Entwickelt für die Primärstromprüfung von Schutzrelais und Leistungssschaltern, sowie für die Inbetriebnahmeprüfung und Wiederholungsprüfung von Umspannstationen und lektrischen Netzen
- Leicht zu transportieren durch modularen Aufbau
- Mit Überhitzungschecks
STS 5000 & TD 5000 - Primary test and power transformer diagnostic system
- Fully automatic
- Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000
- Tan Delta, capacitance, dissipation factor measurements and for exciting current test
- Variable output frequency: 15 - 500 Hz
- 2000 V AC high-pot test
- Local control by large color display
- PADS - Power Apparatus Diagnostic Software for automatic testing, assessment and report
- IEC 61850-9-2 communication protocol
- Patented technology for Capacitance and Tan Delta measurement
- USB interface and Ethernet interface for PC connection
- Compact and lightweight.
STS 4000 & TD 5000 - Primary test and power transformer diagnostic system
- Primary injection testing capabilities: up to 5000 A / 7000 A, with the optional module BUX 5000
- Tan Delta, capacitance, dissipation factor measurements and for exciting current test
- Variable output frequency: 15 - 500 Hz
- 2000 V AC high-pot test
- Local control by large color display
- PADS - Power Apparatus Diagnostic Software for automatic testing, assessment and report
- IEC 61850-9-2 communication protocol
- Patented technology for Capacitance and Tan Delta measurement
- USB interface and Ethernet interface for PC connection
- Compact and lightweight.
TDX 5000 - Tan Delta and Capacitance diagnostic system for power apparatus
- Fully automatic
- Variable output frequency: 15 - 500 Hz
- Output voltage up to 12 kV
- Tan Delta, capacitance, dissipation factor measurements and exciting current test
- PADS - Power Apparatus Diagnostic Software for automatic testing, assessment and report
- USB interface and Ethernet interface for PC connection
- Patented technology for capacitance and Tan Delta measurement
- Light and compact
SFRA 5000 - Sweep frequency response analyzer
- Standalone high accuracy transformer analysis
- Leading wideband accuracy: basic 0.02dB with class leading high frequency performance
- Leading phase accuracy: 0.05 degrees basic
- Wide frequency range: 5Hz to 45MHz
- Full colour VGA display enabling engineer to perform and store measurement in the field without a PC
- PC software included: remote control, tables, graphs and database management of results
- USB, RS232 and LAN interfaces
- LCR mode: fully functional LCR meter to measure transformer LCR parameters
- Various measurement modes: FRA, RMS, LCR, Scope
- Compliant to IEC60076-18 standard
- Light and easy to carry.
STS3000
- Fully automatic
- Variable output frequency: 15 - 500 Hz
- Power dissipation factor test with the module TD 5000 ( voltage up to 12 kV)
- PADS - Power Apparatus Diagnostic Software for automatic testing, assessment and report
- USB interface and Ethernet interface for PC connection
- Compact and lightweight.