Best Products :: Our recommendation

  • Multi-System 5060 MultiSystem 5060 - measuring system

    • Analog input channels 4x standard, 2x HighSpeed (for sensors with or without Hydrotechnik ISDS)
    • Signals 0/4 ... 20 mA • 0/1/2 ... 10 V • 0.5 ... 4.5 V • ± 10 V
    • A/D converter 13 bit
    • Meas. rate HighSpeed 10,000 values per second
    • Meas. rate standard 1,000 values per second
    • Error limits ± 0.15 % FS
    • Frequency input channels 2x (for sensors with or without Hydrotechnik ISDS)
    • Signals 0.25 Hz ... 20 kHz (w.o.D.) • 0.25 Hz ... 5 kHz (w.D.)
    • Measuring rate 10 ns
    • Error limits ± 0.02 % MV
    • Digital input 1x, galvanically separated, 3.5 ... 30 VDC
    • Measuring rate 1,000 values per second
    • Digital output 1x
    • max. load Ub / 10 mA
    • reaction time ≤ 1 ms

  • C.A 8335 QualiSTAR+ CA 8335 Qualistar PLUS Qualistar V2, 4U/4I and even more functions!

    • Voltage ratios: 1 V to 500 kV / Separate or grouped configuration of channels
    • Mixed sensors: 10 mA to 60 kA depending on sensor
    • Combination required: the measurements are performed simultaneously using several different current sensors
    • Transient adjustment level: adjustment of V or A / separate or grouped configuration of channels

  • T5500 - Stainless steel gauges T5500 - Stainless steel gauges Features:

    • Rugged stainless steel construction
    • Socket and case welded
    • Protection IP66
    • Optional ATEX approved
    • Usable to full scale
    • Overload protection 130 %
    • Dry, liquid filled or liquid less (PLUS! gauge)
    • Measuring system stainless steel or Monel
    • Optional contacts
    • Standard: EN 837-1
    • Size: 100 mm, 160 mm
    • Accuracy: 1,0 %
    • Metric Range Min: -1 ... 0 bar
    • Metric Range Max: 0 ... 2500 bar
    • Imperial Range Min: -30 ... 0 in. Hg
    • Imperial Range Max: 0 ... 36.000 psi

  • Multifunktionsbaustein Nemo 96HD Nemo 96HD - Network monitor for low voltage

    • Three-phase line 80...500V (phase-phase)
    • Single-phase 50...290Vy
    • Connection with external dedicated CT
    • Programmable external CT-VT ratio
    • Active energy cl.0,5s

    Optional modules
    • RS485 communication (NT675)
    • RS232 communication (NT676)
    • MBUS communication (NT707)
    • PROFIBUS communication (NT682)
    • LONWORKS communication (NT684)
    • BACNET communication (NT743)
    • RS485 - Energy value storage (NT704)
    • ETHERNET Communication (NT785)
    • Measure temperature from PT100 (NT810)

Sale actions